Cisco (300-615-DCIT) Exam Questions And Answers page 10
A POAP-enabled Cisco Nexus switch will not enter POAP mode.
Which two conditions should be verified? (Choose two.)
Which two conditions should be verified? (Choose two.)
The switch is in bootup process.
The license file is missing on the switch.
Bootflash must contain a special directory named POAP with poap.py file.
No Cisco NX-OS image is present on the bootflash.
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
Which method must a network engineer use to upgrade the BIOS firmware or a Cisco UCS standalone C-Series rack-mount server?
Use the U-ACPI Interface.
Use the Cisco host upgrade utility.
Use the Cisco hardware upgrade utility.
Use the Cisco host firmware policy.
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
Which adjacency server configuration makes two OTV edge devices located in the same site bring up the dual-site adjacency?
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting
An engineer troubleshoots a VXLAN EVPN data center. The applications in the data center fail to reach the DNS server that is located at IP 10.10.10.10. The engineer examines the BGP EVPN routing table and notes that the IP prefix route that covers the DNS server is missing. Which action resolves the issue?
Set the IP prefix route to represent [5]:[0]:[0]:[32]:[10.10.10.10]/224 in the routing table.
Set the IP prefix route to represent [2]:[0]:[0]:[48]:[0050.569f.1285]:[0]:[0.0.0.0]/216 in the routing table.
Configure an IP ARP entry to represent [2]:[0]:[0]:[48]:[0050.569f.1285]:[32]:[10.10.10.10]/272 in the routing table.
Configure an IP ARP entry to represent [4]:[0300.0000.00fc.bd00.0309]:[32]:[10.10.10.10]/136 in the routing table.
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
Refer to the exhibit. An attempt to bind the Ethernet interface to vFC fails. Which action resolves the issue?
Add the FCoE VLAN to the allowed VLAN list.
Configure the FCoE VLAN that corresponds to the vFC VSAN as a private VLAN.
Configure the interface as a trunk port.
Configure the interface to use the native VLAN of the trunk port.
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting
Refer to an exhibit. An engineer is troubleshooting an upgrade failure on a switch. Which action resolves the issue?
Save the system image in NVRAM.
Use the same system image as the kickstart image.
Load a new system image.
Reload the same system image.
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting
Drag and drop the actions from the left onto the faults that they resolve on the right. Not all actions are used.
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting
An engineer must configure Cisco IMC server management NIC for autonegotiation.
Which setting should be selected?
Which setting should be selected?
shared LOM
Cisco card
dedicated
shared LOM EXT
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
A system administrator connects a Cisco Nexus 2248PQ FEX to a fabric interconnect to expand the ports that are available for connecting Cisco UCS C-Series Rack Servers. In Cisco UCS Manager, the administrator does not see the servers connected to this FEX. Which action should be taken to resolve the issue?
The FEX must be exchanged so that it supports the connectivity between fabric interconnects and UCS C-Series servers
The fabric interconnects must be rebooted before the FEX is recognized
The transceivers must be exchanged to support the connectivity between the FEX and the fabric interconnects
The ports that connect the FEX to the fabric interconnects must be configured as server ports
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
During a boot process of a Cisco UCS C-Series Rack Server, an engineer receives a No Signal message from the vKVM and physical video connection. Which set of steps resolves the issue?
1. Disconnect the power cord.
2. Confirm that all cards are properly seated.
3. Connect the power cord and power on the server.
2. Confirm that all cards are properly seated.
3. Connect the power cord and power on the server.
1. Power off the server and disconnect the power cord.
2. Confirm that all cards are properly seated.
3. Connect the power cord and power on the server.
2. Confirm that all cards are properly seated.
3. Connect the power cord and power on the server.
1. Disconnect the power cord.
2. Confirm that all cards are properly seated.
3. Connect the power cord.
2. Confirm that all cards are properly seated.
3. Connect the power cord.
1. Power off the server and disconnect the power cord.
2. Confirm that all cards are available.
3. Connect the power cord and power on the server.
2. Confirm that all cards are available.
3. Connect the power cord and power on the server.
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting