An engineer must place a Cisco UCS B-Series Server in a single server pool in Cisco UCS Manager. The engineer creates a qualification policy, but the server is still seen in multiple pools. Which two actions resolve the issue? (Choose two.)
Set the number of vNICs qualifier inside the Server Pool Policy.
Set the operating system qualifier inside the Server Pool Policy Qualification.
Set the storage capacity qualifier inside the Server Pool Policy Qualification.
Select the Server Pool Policy Qualification from the qualification drop-down menu in the Server Pool Policy.
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting
Which statement describes the rolling EPLD upgrade on a Cisco MDS 9000 Series Switch?
The standby supervisor module is capable of performing the upgrade.
Only the modules that are being upgraded are disrupted.
All modules on the switch are disrupted.
An EPLD upgrade is nondisruptive.
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
The FCoE technology is used in a data center and the MDS switches are configured as Fibre Channel Forwarders. Which configuration should be applied to an MDS switch in order to be used as the best switch to connect by the CNAs in the fabric?
fcoe fcf-priority 512
fcoe fcf-priority 0
no fcoe fcf-priority
fcoe fcf-priority 1024
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
An engineer must modify an overridden policy by changing the number of FCNS database entries to 1500 and then generate a message.
What configuration will accomplish this task?
What configuration will accomplish this task?
event manager applet fcns_policy
event fcns entries max-per-switch 1500
action 1.0 syslog priority warnings msg FCNS DB entries have reached the EEM limit
action 2.0 policy-default
event fcns entries max-per-switch 1500
action 1.0 syslog priority warnings msg FCNS DB entries have reached the EEM limit
action 2.0 policy-default
event manager applet fcns_policy override __fcns_entries_max_per_switch
action 1.0 syslog priority errors "CNS DB entries have reached the EEM limit"
action 2.0 policy-default
action 1.0 syslog priority errors "CNS DB entries have reached the EEM limit"
action 2.0 policy-default
event manager applet fcns_policy override __fcns_entries_max_per_switch
event fcns entries max-per-switch 1500
action 1.0 syslog priority warnings msg FCNS DB entries have reached the EEM limit
event fcns entries max-per-switch 1500
action 1.0 syslog priority warnings msg FCNS DB entries have reached the EEM limit
event manager applet fcns_policy
action 1.0 syslog priority warnings msg FCNS DB entries have reached the EEM limit
action 2.0 event-default
action 1.0 syslog priority warnings msg FCNS DB entries have reached the EEM limit
action 2.0 event-default
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
An engineer is implementing NPV mode on a Cisco MDS 9000 Series Switch.
Which action must be taken?
Which action must be taken?
NPIV must be enabled on the upstream switch.
The FCNS database must be disabled in the fabric.
A port channel must be configured to the upstream switch.
All switches in the fabric must be Cisco MDS switches.
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
Refer to the exhibit. A Postman call to a Cisco APIC fails. The access credentials were confirmed to be configured as expected. Which action resolves the issue?
Change operation type to POST
Modify the protocol to HTTP
Change the IP address to a domain name
Modify the target protocol type to XML
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting
Which two components should be checked when a Cisco Nexus 9000 Series Switch fails to boot using POAP? (Choose two.)
POAP feature license
DHCP server to bootstrap IP information
image noted in the script file against switch bootflash
script signed with security key
TFTP server that contains the configuration script
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
Which statement describes monitoring Fibre Channel traffic on a Cisco UCS 6332 Fabric Interconnect?
Fibre Channel traffic is monitored only on one vHBA per server.
Fibre Channel traffic is capable to be monitored as it is encapsulated as FCoE.
The monitoring of Fibre Channel traffic is limited to the default VSAN.
The destination port for monitoring must be an unassigned Fibre Channel port.
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
Refer to the exhibit. The integration between Cisco UCS Manager and Cisco UCS Central failed. Which action resolves the issue?
Implement the consistent NTP source between the appliances
Implement the connectivity between the appliances through a firewall
Configure the certificate between the appliances
Configure the shared secret key between the appliances
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting
Refer to the exhibit. A network engineer is configuring the FCoE N_Port virtualization storage area network. After the initial implementation, server 11 fails to connect to the disk array. Which action resolves the issue?
On MDS interface vfc 1/1, change switchport mode configuration to VF
On N9K interface vfc11, change switchport mode configuration to NP
On N9K interface vfc11 and MDS interface vfc 1/1, change switchport mode configuration to F
On N9K interface vfc11 and MDS interface vfc 1/1, change switchport mode configuration to E
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting