Cisco (300-615-DCIT) Exam Questions And Answers page 3
Refer to the exhibit.
The STP priority of N7K-1 and N7K-2 are the lowest in the network.
Which statement describes STP on the vPC?
The STP priority of N7K-1 and N7K-2 are the lowest in the network.
Which statement describes STP on the vPC?
N7K-1 appears as the STP root.
N7K-1 preempts N7K-2 as the STP root.
N7K-2 appears as the STP root.
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting
Which two statements describe the process of performing an EPLD upgrade on a Cisco MDS 9000 Series Switch? (Choose two.)
The upgrade is performed from the standby supervisor module.
The upgrade process disrupts only the module that is being upgraded.
The upgrade is performed on the active supervisor.
If an upgrade is interrupted, the upgrade continues after a connection is restored.
Modules must be online to be upgraded.
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
Refer to the exhibit. The EEM script is applied in the default VDC to collect the outputs during high CPU utilization on the Cisco Nexus 7000 Series Switch for all VDCs. Which configuration set must be added to the script to fix the issue?
switch(config-applet)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1
switch(config-applet)# action 0.2 cli enable
switch(config-applet)# action 0.5 cli switchto vdc Core
switch(config-applet)# action 0.8 cli switchto vdc Distribution
switch(config-applet)# action 0.2 cli enable
switch(config-applet)# action 0.5 cli switchto vdc Core
switch(config-applet)# action 0.8 cli switchto vdc Distribution
switch(config-applet)# event snmp 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1
switch(config-applet)# action 0.2 cli config t
switch(config-applet)# action 0.5 cli switchto vdc Core
switch(config-applet)# action 0.8 cli switchto vdc Distribution
switch(config-applet)# action 0.2 cli config t
switch(config-applet)# action 0.5 cli switchto vdc Core
switch(config-applet)# action 0.8 cli switchto vdc Distribution
switch(config-applet)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1
switch(config-applet)# action 0.2 cli config t
switch(config-applet)# action 0.5 cli switchto vdc Core
switch(config-applet)# action 0.8 cli switchto vdc Distribution
switch(config-applet)# action 0.2 cli config t
switch(config-applet)# action 0.5 cli switchto vdc Core
switch(config-applet)# action 0.8 cli switchto vdc Distribution
switch(config-applet)# event snmp oid 1.3.6.1.4.1.9.9.109.1.1.1.1.6.1 get-type exact entry-op ge entry-val 50 poll-interval 1
switch(config-applet)# action 0.2 cli enable
switch(config-applet)# action 0.5 cli switchto vdc Core
switch(config-applet)# action 0.8 cli switchto vdc Distribution
switch(config-applet)# action 0.2 cli enable
switch(config-applet)# action 0.5 cli switchto vdc Core
switch(config-applet)# action 0.8 cli switchto vdc Distribution
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting
Refer to the exhibit. Sw1 and Sw2 are Cisco Nexus 9000 Series Switches that run Cisco NX-OS. They are VTEPs in the same vPC domain. What occurs in this scenario?
Sw1 drops all traffic because there is no (S, G) OIF list to encapsulate VXLAN multicast packets and send them to the underlay network through the uplink interfaces.
Sw1 performs the VXLAN multicast encapsulation and decapsulation for all traffic associated with the VXLAN VNIs.
Sw1 and Sw2 perform the VXLAN multicast encapsulation and decapsulation for all traffic that is associated with the VXLAN VNIs, depending on the hashing.
Sw2 does not send an IP PIM register to the rendezvous point for the multicast group of the VXLAN VNI.
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting
A network engineer experiences the error DDR3_P1_B1_ECC when upgrading Cisco UCS firmware. Which action resolves the issue?
Reset the DIMM
Reset the BMC firmware
Reflash the controller firmware
Reflash the DIMM
Data Center Troubleshooting Methodologies
Data Center Network Services Troubleshooting
Refer to the exhibit. A network engineer creates an EEM script to trigger an SNMP notification when a user enters configuration mode, but the trap is not received when the condition is met. Which action resolves the issue?
Append action 2.0 event-default to the script
Append action 2.0 cli conf t to the script
Modify snmp-trap strdata Configuration changed to syslog msg Configuration changed
Modify cli match conf t to snmp match conf t
Data Center Infrastructure Troubleshooting
Data Center Troubleshooting Methodologies
A server administrator attempts to change the Cisco IMC KVM certificate to one that is signed by a private CA, but the certificate is not accepted. What causes this process to fail?
using a certificate with a password-protected private key
using RSA encryption in the generation of the certificate
using AES encryption in the generation of the certificate
omitting the public IP address of the Cisco IMC in the SAN
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
Refer to the exhibit. One of the vPC VTEPs fails to route VXLAN traffic to vPC connected hosts. When the issue was being diagnosed, it was discovered that the packets that were expected to be forwarded to the MAC address on the SWITCH-VTEP-1 are instead forwarded to the MAC address on SWITCH-VTEP-2 and then dropped. Which action resolves the issue?
Configure a distributed anycast gateway on both peers
Configure ip arp synchronize under the VPC domain on both peers
Configure peer-gateway under the VPC domain on both peers
Configure a different secondary IP address for one of the vPC peers
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting
Refer to the exhibit. The connection between a Cisco Nexus 5548UP switch and a Cisco MDS switch fails to initialize. What is the cause of the issue?
VSAN 1 is suspended.
The SFP is unsupported.
Trunk mode must be activated.
The interface is in an incorrect mode.
Data Center Infrastructure Troubleshooting
Data Center Network Services Troubleshooting
Refer to the exhibit. An engineer monitors a Cisco UCS server logs and discovers a blade discovery issue. Which procedure resolves the issue?
1. Verify the server power module.
2. Decommission the faulty module.
3. Insert a new power module.
4. Recommission the new module.
2. Decommission the faulty module.
3. Insert a new power module.
4. Recommission the new module.
1. Verify that server platform power is failed
2. Resolve the platform power issue.
3. Reboot the server.
4. Recommission the server.
2. Resolve the platform power issue.
3. Reboot the server.
4. Recommission the server.
1. Verify the FSM status on the server.
2. Decommission the impacted server.
3. Reset the slot where the server is located.
4. Recommission the server.
2. Decommission the impacted server.
3. Reset the slot where the server is located.
4. Recommission the server.
1. Verify that the power on self-test operation is failed.
2. Verify that the server firmware is corrupted.
3. Decommission the server firmware
4. Recommission the server with new firmware.
2. Verify that the server firmware is corrupted.
3. Decommission the server firmware
4. Recommission the server with new firmware.
Data Center Infrastructure Troubleshooting
Data Center Infrastructure Troubleshooting